1、 After closing and using, there is a phenomenon of floor drain. If users find that the equipment has floor drains after production, they should proceed with the following actions.
First, check if the filling nozzle orifice is damaged, and then remove the filling nozzle to repair the orifice. The diameter of the orifice should be less than 7.5mm. After repairing the aperture, gently grind the flat surface of the aperture on a water sanded paper. Check again if the ball valve inside the filling head is damaged, and replace the ball valve promptly if damaged.
2、 The crank of the water bottle packaging machine does not operate properly after starting up. What should be done in this situation?
The fixing rod on the filling machine is leaning downwards, and the inner and outer tubes of the syringe are firmly pressed when pushing the liquid, causing the crank to not rotate. The nut should be loosened, and the upper fixing rod should be moved up to the appropriate position before tightening the nut. If the inner and outer tubes are not clean during the assembly of the syringe and become stuck, the syringe needs to be removed for cleaning. Observe the end of the injection system at the bearing area. If it cannot function properly, it needs to be reinstalled.
3、 The equipment has a faulty capacity error, or the capacity error is significant. It is reported that in this situation, it is generally necessary for the user to make adjustments.
There is air in the liquid pipe of the filling machine, and users can press the foot switch multiple times to exhaust; If the inlet pipeline is not tightly sealed and there is air leakage, it is necessary to tighten the connecting pipe; If the operation or filling speed is too fast, slow down the speed appropriately; If the liquid level in the material cylinder is low, it will keep the liquid level at 1.52 meters. In addition, when filling large specifications, if the material tank is not filled enough, resulting in unstable liquid level, users can increase the amount of filling or close the ball valve above the filling head again, and reset the filling time.